28
Daman Products Company, Inc. •
1811 North Home Street • Mishawaka, IN 46545-7267
Tel: 800.959.7841 574.259.7841 •
Fax: 800.241.7664 • Email: sales@daman.com • www.daman.com
P, S
Port code Valve mtg.
0.25-20 UNC x
0.75 [19] DP
M6 ISO 6H x
0.75 [19] DP
Manifold mtg.
0.38-16 UNC x
0.75 [19] DP
M10 ISO 6H x
0.75 [19] DP
B, M, T
BSPT • ISO 7
T
0.75 1.00 none
BSPP • ISO 1179
ISO • ISO 6149
B
M
0.75 1.00 none
M27 M33
0.38
0.38
M14 none
P
T
ABBA
P
T
GA
45
30
25
15
15
5
Velocity (fps)
T passage - D05HP
P passage - D05HP
Flow (gpm)
Rated ow Pressure 25 gpm @ 15 fps
Rated ow Tank 41 gpm @ 15 fps
Flow Curve
D05 High Flow Parallel Circuit Manifold
Valve Spacing
3.25 inch
82.6 mm
5.00 inch
127.0 mm
5
3
No. of Stations
Available with
spacing code 5
Available with
spacing code 3
02...14
01...21
Aluminum
Available with
spacing code 5
Available with
spacing code 3
02...14
01...21
Ductile Iron
Valve Pattern
ISO 4401-05-04
NFPA T3.5.1-D05
See Tech Information
D05
Circuit
Parallel Circuit
High Flow
HP
Options
See next page for available
options and ordering codes.
apx. weight ferrous
lb [kg]
19
[9]
7
[3]
3.25
[82.6]
* 01
apx. weight alum
lb [kg]
“A” length (code 3 spa.)
inch [mm]
apx. weight ferrous
lb [kg]
--
--
--
38
[17]
12
[5]
6.50
[165.1]
02
48
[22]
18
[8]
8.25
[209.6]
57
[26]
17
[8]
9.75
[247.7]
03
77
[35]
26
[12]
13.25
[336.6]
75
[34]
22
[10]
13.00
[330.2]
04
106
[48]
33
[15]
18.25
[463.6]
85
[39]
27
[12]
16.25
[412.8]
05
135
[61]
41
[19]
23.25
[590.6]
113
[51]
33
[15]
19.50
[495.3]
06
164
[74]
48
[22]
28.25
[717.6]
132
[60]
38
[17]
22.75
[577.9]
07
188
[85]
56
[25]
33.25
[844.6]
151
[69]
43
[20]
26.00
[660.4]
08
222
[101]
63
[29]
38.25
[971.6]
170
[77]
48
[22]
29.25
[743.0]
09
251
[114]
71
[32]
43.25
[1098.6]
189
[86]
53
[24]
32.50
[825.5]
10
280
[127]
79
[36]
48.25
[1225.6]
208
[94]
58
[26]
35.75
[908.1]
11
309
[140]
87
[39]
53.25
[1352.6]
226
[103]
63
[29]
39.00
[990.6]
12
338
[153]
95
[43]
58.25
[1479.6]
245
[111]
68
[31]
42.25
[1073.2]
13
367
[166]
103
[47]
63.25
[1606.6]
264
[120]
74
[34]
45.50
[1155.7]
14
283
[128]
79
[36]
48.75
[1238.3]
15
302
[137]
84
[38]
52.00
[1320.8]
16
320
[145]
89
[40]
55.25
[1403.4]
17
339
[154]
94
[43]
58.50
[1485.9]
18
358
[162]
99
[45]
61.75
[1568.5]
19
377
[171]
104
[47]
65.00
[1651.0]
20
396
[180]
110
[50]
68.25
[1733.6]
21
396
[180]
111
[50]
68.25
[1733.6]
apx. weight alum
lb [kg]
“A” length (code 5 spa.)
inch [mm]
No. of stations
P
T
2.00
5.00
0.44
4.13
1.17
P
0.38
4.00
T
3.22
2.72
5.00 [127.0] TYP
3.25 [82.6] TYP
2.28
1.38
0.44
0.44
5.00
4.13
0.44
0.88
0.56
1.38
1.50
3.13
3.19
3.25 [82.6] TYP
5.00 [127.0] TYP
1.56
A
B
GA
A
B
A
B
[57.9]
[81.0]
[22.2]
[39.7]
[79.4]
[38.1]
[14.3]
[34.9]
[34.9]
[104.8]
[11.1]
[127.0]
[11.1]
[11.1]
[127.0]
[104.8]
[11.1]
[9.5]
[50.8]
[101.6]
[29.7]
[81.7]
[69.2]
"A" (See chart)
GA
NPTF • ANSI B1.20.3
Port Threads
SAE • ISO 11926
S
P
0.75
P,A,B T
1.00
X,Y,L
optional
0.25
-12 -16 -6
0.38
-6
Specifications, descriptions, and dimensional data are subject to
correction or change without notice or incurring obligation.
Download latest catalog page revisions at www.daman.com.
Parallel Circuit
* Length of 01 station with relief cavity is 4.50 [114.3]. Gauge port not available on 01 station.
All mounting hardware
is supplied. See page
64 for itemized list.
Ordering Information
/
Material
Valve
Pattern
Circuit
No. of
Stations
Valve
Spacing
Port
Threads
Options
Material
D
Working pressure should
be considered in accordance
with ISO 4413 to determine
appropriate material type.
Ductile Iron - D4512
5000
psi 34.5 MPa
Aluminum - 6061-T6
3000
psi 20.7 MPa
A
For coating options
see pages 245-246.
29
Daman Products Company, Inc. •
1811 North Home Street • Mishawaka, IN 46545-7267
Tel: 800.959.7841 574.259.7841 •
Fax: 800.241.7664 • Email: sales@daman.com • www.daman.com
Pilot Ports
X port (USA std)
NFPA T3.5.1-D05 Alt-B
Omit if pilot ports not required
Y port (USA std)
NFPA T3.5.1-D05 Alt-B
X & Y ports (USA std)
NFPA T3.5.1-D05 Alt-B
X port ISO 4401-05-05
NFPA T3.5.1-D05 Alt-A
Y port ISO 4401-05-05
NFPA T3.5.1-D05 Alt-A
X & Y ports ISO 4401-05-05
NFPA T3.5.1-D05 Alt-A
L ports
Proportional valves
3
13
2
4
24
5
1
Relief cavity is located
left of the isolation.
Relief cavity is located
right of the isolation.
Two relief cavities, one
each side of isolation.
L
R
D
Specify when using a combi-
nation of cavity and isolation
options. Cavities do have
solenoid clearance.
Available with
spacing code 5
Available with
spacing code 3
PA...PF
PA...PJ
Omit if P isolation not required
Available with
spacing code 5
Available with
spacing code 3
TA...TF
TA...TJ
Omit if T isolation not required
Common cavity:
With solenoid clearance.
C-10-2 (P in nose)
For valves w/1" hex max.
Omit if cavity not required
Sun Cavity
T-3A (P in nose)
See Tech Info for valves.
S
C
A
GA
AA
5.00
P
4.00
T
BBB
P
T
[101.6]
[127.0]
A
B
Y
X
2.00
[50.8]
Pilot port:
X on option 1 and 13,
Y on option 4 and 24.
[19.1]
0.75
X on option 2 and 24,
Y on option 3 and 13,
Pilot port:
1.00
[25.4]
L on option 5.
3.25
[82.6]
Valve cavity location when
Valve cavity location
cavity, or cavity-isolation
combination L or D is specied.
for cavity-isolation
"A" (See chart previous page)
combination R or D.
P
T
ABBA
P
T
GAY X
Options - D05 High Flow Parallel Manifold
T
P
T
Parallel Circuit with L
Parallel Circuit with X & Y
ISOLATIONS
Daman isolation options allow a manifold
to have two independent pressure and/or
tank ports. Isolations are drilled rather
than plugged to ensure a leakproof and
failproof isolation.
Ordering
code letter:
A
B
C
D
E
F
G
H
J
01 & 02
02 & 03
03 & 04
04 & 05
05 & 06
06 & 07
07 & 08
08 & 09
09 & 10
02-10
03-11
04-12
05-13
06-14
07-15
08-16
09-17
10-18
3.25 [82.6] spacing
A
B
C
D
E
F
01 & 02
02 & 03
03 & 04
04 & 05
05 & 06
06 & 07
02-07
03-08
04-09
05-10
06-11
07-12
5.00 [127.0] spacing
* Isolation is
between stations:
Available #
of stations:
Tank Isolation
Pressure Isolation
* Stations are numbered left to right.
Pilot port location dimensions vary on (1) station manifolds
and manifolds with isolations. Contact Daman for cavity
locations if critical.
Pilot ports available from 01-11 stations (3.25
spacing); 02-07 stations (5.00 spacing)
NOTES:
1) The GA port is not available
on a (1) station manifold.
2) The GA port is not available
when a pressure isolation is
located between stations 1 & 2.
3) Some cavity and isolation
combinations are not possible.
Consult factory to determine
availablity.
Ordering Information
... /
Pilot Ports Cavity
Pressure
Isolation
Tank Isolation
Cavity &
Isolation
Combinations
P
T
ABBA
P
T
GA AB
P
T
AB
BA
P
T
AB
P
T
AB
BA
P
T
AB
Parallel Circuit with Isolations
Cavity & Isolation CombinationsParallel Circuit with Cavity
Valves with P in the nose and T out the
side must be used.
Manifold shown with P isolation between 1
& 2 (PA), and T isolation between 2 & 3 (TB).
Option code L
Cavity left of isolation
Option code R
Cavity right of isolation
Option code D includes both cavities
Cavity & Isolation
Combinations
Cavity
Standard
Manifolds
Custom
Products
Cover
Plates
Valve
Adaptors
SubplatesServo Valve
Subplates
Tapping
Plates
DIN Cartridge
Valve Bodies
Header and
Junction Blocks
Technical
Information